This system occupies little space, is easy to operate, and has a wide application range. When used for disposing industrial water, the reverse osmosis device does not consume large amounts of acids and alkalis, and there is no secondary pollution. In addition, its operation cost is also low.


DUBAI Project - 2000L/Hour
Electronic industry water: integrated circuit, silicon wafer, display tube and other electronic components.
Pharmaceutical industry water: large infusion, injection, tablets, biochemical products, equipment cleaning, etc.
Chemical industry process water: chemical circulating water, chemical products manufacturing, etc.
Electric industry boiler feeding water: thermal power generation boiler, low pressure boiler power system.
Food industry water: purified drinking water, beverage, beer, alcohol, health products, etc.
Seawater and saline water desalination: islands, ships, marine drilling platforms.
Raw water → Raw water tank → Raw water pump → Sand filter → Carbon filter → Safety filter → (High pressure pump) → One stage RO → Middle water tank → (High pressure pump) → Two stage RO → Stainless steel pure water tank → Pure water pump → Point of use
SRI LANKA - 1000L/H
UK - 1000L/H
SOUTH AFRICA - 2000L/H



Project References: DUBAI (3000L/H), SYRIA (500L/H), KUWAIT (1000L/H)
Anion Cation Mixing Bed
Ozone Generator
Ultraviolet Sterilizer
| Model | Capacity(T/H) | Power(KW) | Recovery(%) | 1-Stage Cond. | 2-Stage Cond. | EDI Cond. |
|---|---|---|---|---|---|---|
| R0-500 | 0.5 | 0.75 | 55-75 | ≤10μs/cm | 2-3μs/cm | ≤0.5μs/cm |
| R0-1000 | 1.0 | 2.2 | 55-75 | |||
| R0-2000 | 2.0 | 4.0 | 55-75 | |||
| R0-5000 | 5.0 | 7.5 | 55-75 | |||
| R0-10000 | 10.0 | 11 | 55-75 | |||
| R0-20000 | 20.0 | 15 | 55-75 |
| No | Item | Description |
|---|---|---|
| 1 | Voltage | AC380V-3phase |
| 2 | Component | Sand + Carbon + Soften + Precision + RO filters |
| 3 | Capacity | 500L/H - 5000L/H (Customized) |
| 4 | Principle | Physical filtration + Reverse osmosis |
| 5 | Control | Button or PLC + Touch screen |
The main purpose of pretreatment is to eliminate suspended matter, microorganisms, colloids, and organic matter in raw water. This ensures the water meets the requirements for reverse osmosis inflow.