Discount Cosmetic industrial pure water treatment machine RO water Treatment machine Manufacturer, Suppliers

Medical chemical cosmetic pure water production plant RO water treatment system The RO water purifying system firstly produced for such industries as cosmetics, pharmacy, food and electronics has been deeply favored by users for its stable water quality and simple operation. The system solves the troubles of frequent regeneration and cleaning during the use of ion exchanging water purifier. By adopting physical principle, it enables the water to pass the reverse osmosis film with a diameter of one ten-thousandth of a micron and separates impurities, ion, microbes and colloids in the water, so as to meet the water requirements in cosmetics, pharmacy, electronics and food industries.

Product Description

This system occupies little space, is easy to operate, and has a wide application range. When used for disposing industrial water, the reverse osmosis device does not consume large amounts of acids and alkalis, and there is no secondary pollution. In addition, its operation cost is also low.

💎
High Efficiency: Desalting rate >99%, machine desalting rate >97%. 98% of organic matters, colloids and bacteria can be removed.
⚙️
Automation: High operation automation degree. It is unattended with automatic stop/start and timed flushing controlled by IC microcomputer.
🌐
Quality Parts: Imported parts account for over 90% of the system components.
The system occupies little space and is easy to operate.
No consumption of large amounts of acids/alkalis, ensuring no secondary pollution.
Low electric conductivity: One stage ≤ 10μs/cm, Two stage 2-3 μs/cm, EDI ≤ 0.5μs/cm.
Customizable capacity: 500L/H, 1000L/H, 1500L/H up to 6000L/H.

Design Basis and Principle

  • (1) Water output: 500L/H-5000L/H
  • (2) Feed water requirements: Municipal water, reservoir water, ground water
  • (3) Outflow water standard: Conductivity ≤10μs, accords with national drinking water standards.
  • (4) Water feed method: Continuous
  • (5) Power supply: Single phase, 380V, 50HZ, ground resistance 10Ω.
  • (6) Design range: From raw water tank to terminals.

DUBAI Project - 2000L/Hour

Application Fields

Electronic industry water: integrated circuit, silicon wafer, display tube and other electronic components.

Pharmaceutical industry water: large infusion, injection, tablets, biochemical products, equipment cleaning, etc.

Chemical industry process water: chemical circulating water, chemical products manufacturing, etc.

Electric industry boiler feeding water: thermal power generation boiler, low pressure boiler power system.

Food industry water: purified drinking water, beverage, beer, alcohol, health products, etc.

Seawater and saline water desalination: islands, ships, marine drilling platforms.

Flowchart for Two-stage Type

Raw water → Raw water tank → Raw water pump → Sand filter → Carbon filter → Safety filter → (High pressure pump) → One stage RO → Middle water tank → (High pressure pump) → Two stage RO → Stainless steel pure water tank → Pure water pump → Point of use

SRI LANKA - 1000L/H

UK - 1000L/H

SOUTH AFRICA - 2000L/H

Project References: DUBAI (3000L/H), SYRIA (500L/H), KUWAIT (1000L/H)

Anion Cation Mixing Bed

Ozone Generator

Ultraviolet Sterilizer

Model Capacity(T/H) Power(KW) Recovery(%) 1-Stage Cond. 2-Stage Cond. EDI Cond.
R0-5000.50.7555-75≤10μs/cm2-3μs/cm≤0.5μs/cm
R0-10001.02.255-75
R0-20002.04.055-75
R0-50005.07.555-75
R0-1000010.01155-75
R0-2000020.01555-75
No Item Description
1VoltageAC380V-3phase
2ComponentSand + Carbon + Soften + Precision + RO filters
3Capacity500L/H - 5000L/H (Customized)
4PrinciplePhysical filtration + Reverse osmosis
5ControlButton or PLC + Touch screen

Pretreatment Equipment Introduction

The main purpose of pretreatment is to eliminate suspended matter, microorganisms, colloids, and organic matter in raw water. This ensures the water meets the requirements for reverse osmosis inflow.

Multi-medium filter: Removes larger particles and turbidity.
Active carbon adsorption: Removes odors, chlorine, and organics.
Secondary filter: Further refines water quality before RO.
Frequently Asked Questions
1. What is the desalting efficiency of this RO system?
The system features a reverse osmosis desalting rate of over 99%, and a machine desalting rate of over 97%, effectively removing bacteria and organics.
2. Does the system require manual monitoring?
No, the system is highly automated and can operate unattended. It includes automatic start/stop functions based on water levels and timed flushing.
3. Can the water production capacity be customized?
Yes, we can produce different types based on requirements, ranging from 500L/H, 1000L/H, up to 20,000L/H or more.
4. What are the requirements for the feed water?
The system is designed to handle municipal water, reservoir water, and ground water as raw feed sources.
5. Is the operation cost high for industrial use?
No, the system is designed for low operation costs and does not consume large amounts of chemical acids or alkalis, making it eco-friendly.
6. What is the typical conductivity of the finished water?
Depending on the configuration, one-stage RO reaches ≤ 10μs/cm, two-stage reaches 2-3μs/cm, and EDI systems can reach ≤ 0.5μs/cm.